experimental

Entry: sensitivity - showing version 7

URI: https://terra-vocabulary.org/ncl/DataTerraRepositoryFairIncubator/motsClefs/c_e9de9e08

The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)

Core metadata

is a observable property | Concept
changed on 17 Nov 2023 08:31:48.962
submitted byHélène Bressan
accepted on 20 May 2022 09:42:08.416

Download formats available

Download formats available

RDF ttl with metadata
RDF/XML with metadata
JSON-LD with metadata
CSV with metadata

All metadata properties

date accepted 20 May 2022 09:42:08.416
date submitted 20 May 2022 09:41:39.089
definition
entity sensitivity
source graph graph

description The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)
item class observable property | Concept
label
en sensitivity
fr Sensibilité
modified 17 Nov 2023 08:31:48.962
notation c_e9de9e08
register mots clefs
status status experimental
submitter
account name h.bressan@brgm.fr
name Hélène Bressan

type register item
version info 7
Pane is loading...
Select tab to expand

Definition

description The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)
exact match c 5c554e1b
in scheme Vocabulaire des mots clefs
label
en sensitivity
fr Sensibilité
pref label
en sensitivity
fr Sensibilité
same as c 5c554e1b
source epos
status submitted
top concept of Vocabulaire des mots clefs
type observable property | Concept
was attributed to Pôle FormaTerre