Entry: C-SAR - showing version 3
URI: https://terra-vocabulary.org/ncl/FAIR-Incubator/earthsciencesensors/c_ad89b099
The C-SAR instrument is an active phased array antenna providing fast scanning in elevation (to cover the large range of incidence angle and to support ScanSAR operation) and in azimuth (to allow use of TOPS technique to meet the required image performance). To meet the polarisation requirements, it has dual channel transmit and receive modules and H/V-polarised pairs of slotted waveguides. It has an internal calibration scheme, where transmit signals are routed into the receiver to allow monitoring of amplitude/phase to facilitate high radiometric stability. SENTINEL-1's metallised carbon-fibre-reinforced-plastic radiating waveguides ensure good radiometric stability even though these elements are not covered by the internal calibration scheme. The digital chirp generator and selectable receive filter bandwidths allow efficient use of on-board storage considering the ground range resolution dependence on incidence angle.
Core metadata
is a | Concept | Sensor |
changed on | 1 Dec 2023 10:43:54.341 |
submitted by | Viqui Agazzi |
accepted on | 29 Sep 2022 09:14:26.556 |
Download formats available
RDF ttl | with metadata |
RDF/XML | with metadata |
JSON-LD | with metadata |
CSV | with metadata |
All metadata properties
date accepted |
29 Sep 2022 09:14:26.556
|
||||
date submitted |
29 Sep 2022 09:11:15.067
|
||||
definition |
|
||||
item class |
Concept
| Sensor
|
||||
label |
C-SAR
|
||||
modified |
1 Dec 2023 10:43:54.341
|
||||
notation |
c_ad89b099
|
||||
register |
earthsciencesensors
|
||||
status |
status experimental
|
||||
submitter |
|
||||
type |
register item
|
||||
version info |
3
|
Definition
alt label |
C-Band Synthetic Aperture Radar
|
broader |
Imaging Radars
|
definition |
The C-SAR instrument is an active phased array antenna providing fast scanning in elevation (to cover the large range of incidence angle and to support ScanSAR operation) and in azimuth (to allow use of TOPS technique to meet the required image performance). To meet the polarisation requirements, it has dual channel transmit and receive modules and H/V-polarised pairs of slotted waveguides. It has an internal calibration scheme, where transmit signals are routed into the receiver to allow monitoring of amplitude/phase to facilitate high radiometric stability. SENTINEL-1's metallised carbon-fibre-reinforced-plastic radiating waveguides ensure good radiometric stability even though these elements are not covered by the internal calibration scheme. The digital chirp generator and selectable receive filter bandwidths allow efficient use of on-board storage considering the ground range resolution dependence on incidence angle.
|
exact match |
ed400e7c 229e 48be 9a93 84f2fc864448
|
label |
C-SAR
|
pref label |
C-SAR
|
type |
Concept
| Sensor
|